Error:80040419 Satori (SORTING) STO2=2 Satori (Dosort) output MRE1=54 -2147220455 CallDoProcess() failed. (error 80040419) Satori
Not enough pieces

Error:80040419 Satori (SORTING) STO2=2 Satori (Dosort) output MRE1=54 -2147220455 CallDoProcess() failed. (error 80040419) Satori
MRE1=92 -2147467259 SaveReport failed to save the file "0429C038" for report 364. (error 80004005)
satoriTemplateClass standard-letter
records_count 287
permit_number 892
piece_height 8.5
piece_weight 0
piece_width 0
piece_thickness 0.0294
post_office_drop_date 2021-03-24
presort_class standard
post_office_drop_date. 2021-03-24
- letter - flat - postcard
firstClass standard nonprofit
The problem 80040421 is not always Unable to allocate any sequence numbers
This time the problem was missing permits to execute the presorting of the requests
The solution is to make sure these permits exists and the problem will go away
Also, If you have already done the configuration in the past know that the configuration file exists in the following folder C:/WINDOWS
The file name is mrtk.ini
If you are confronted with the following issue with BCC Architect, the best solution is to take the latest updates available on their website https://portal.bccsoftware.com/
Error: 404 ISSUE WriteMailDatToZip MRE1=92 -2147220468 SaveReport failed to save the file “0106A220” for report 364. (error 8004040c)
Download on this page
Error: The sort failed because there are no more unique mailpiece sequence numbers for your Mailer ID.
Please select a later mailing date or obtain another Mailer ID
Cause
The USPS requires that sequence numbers remain unique for 45 days. When the Sequence mail pieces parameter is set to Automatic, the Bulk Mailer system keeps track of the date and the sequence numbers used. The program also looks for a continuous sequential block of numbers large enough for all the records that are being sorted; if it does not find a large enough block of sequential numbers available, it will produce this error.
Note: Bulk Mailer does not allow sequence numbers to be reused for 90 days.
Resolution
1 . Obtain another Mailer ID to use until the current Mailer IDs sequence numbers are released for re-use. Once a second mailer ID is obtained through the Business Customer Gateway, create a second permit by making a copy of the current one, and use the new Mailer ID in that one.
2. Sometimes restarting the whole server could do the trick
More Information
How to request an additional Mailer ID
Article Number000002763
Satori Architect;
Satori OfficeJun 12, 2019•Knowledge Base ArticleProductsSatori Architect;Satori OfficeArticle
When running a mail sort, the following error occurs:
80040421 – Unable to allocate any sequence numbers
Cause
The
USPS requires that sequence numbers remain unique for 45 days. When the
Sequence mail pieces parameter is set to Automatic, the Bulk Mailer
system keeps track of the date and the sequence numbers used. The
program also looks for a continuous sequential block of numbers large
enough for all the records that are being sorted; if it does not find a
large enough block of sequential numbers available, it will produce this
error.
Note: Satori Architect
and Office do not allow sequence numbers to be reused for 120 days from
the mailing date specified in the sort settings.
Resolution
Obtain another Mailer ID to use until the current Mailer ID’s sequence numbers are released for re-use. Once a second Mailer ID is obtained through the Business Customer Gateway, create a second permit by making a copy of the current one, and use the new Mailer ID in the second permit.
More Information
How to request an additional Mailer ID
Article Number000002802