Error:80040419 Satori (SORTING) STO2=2 Satori (Dosort) output MRE1=54 -2147220455 CallDoProcess() failed. (error 80040419) Satori

Error:80040419 Satori (SORTING) STO2=2 Satori (Dosort) output MRE1=54 -2147220455 CallDoProcess() failed. (error 80040419) Satori

Not enough pieces

Categories
General Satori Architect

How to fix Satori 80004005 error ?

MRE1=92 -2147467259 SaveReport failed to save the file "0429C038" for report 364. (error 80004005)

Make Sure All parameters are passed

satoriTemplateClass  standard-letter
records_count        287 
permit_number        892 
piece_height         8.5 
piece_weight          0
piece_width           0 
piece_thickness       0.0294 
post_office_drop_date  2021-03-24 
presort_class          standard 
post_office_drop_date. 2021-03-24 

postage category

- letter
- flat
- postcard
  

presort class

firstClass 
standard 
nonprofit 
Categories
Satori Architect

How to fix Satori issue 80040421 ?

The problem 80040421 is not always Unable to allocate any sequence numbers

This time the problem was missing permits to execute the presorting of the requests

The solution is to make sure these permits exists and the problem will go away

Also, If you have already done the configuration in the past know that the configuration file exists in the following folder C:/WINDOWS

The file name is mrtk.ini 

Categories
Satori Architect

How to update BCC Architect Software ?

If you are confronted with the following issue with BCC Architect, the best solution is to take the latest updates available on their website https://portal.bccsoftware.com/

Error: 404 ISSUE WriteMailDatToZip MRE1=92 -2147220468 SaveReport failed to save the file “0106A220” for report 364. (error 8004040c)

Download on this page

Categories
Satori Architect USPS

What is Error 80040419 : The sort failed because there are no more unique mailpiece sequence numbers for your Mailer ID ?


 Error:  The sort failed because there are no more unique mailpiece sequence numbers for your Mailer ID.

Please select a later mailing date or obtain another Mailer ID
Cause 

The USPS requires that sequence numbers remain unique for 45 days. When the Sequence mail pieces parameter is set to Automatic, the Bulk Mailer system keeps track of the date and the sequence numbers used. The program also looks for a continuous sequential block of numbers large enough for all the records that are being sorted; if it does not find a large enough block of sequential numbers available, it will produce this error.  

Note: Bulk Mailer does not allow sequence numbers to be reused for 90 days.

Resolution

1 . Obtain another Mailer ID to use until the current Mailer IDs sequence numbers are released for re-use. Once a second mailer ID is obtained through the Business Customer Gateway, create a second permit by making a copy of the current one, and use the new Mailer ID in that one.

2. Sometimes restarting the whole server could do the trick

More Information
How to request an additional Mailer ID

Article Number000002763

Categories
Satori Architect USPS

What is Error: 80040421 quadient/satori architect server ?

Error: 80040421 – Unable to allocate any sequence numbers

Satori Architect;

Satori OfficeJun 12, 2019•Knowledge Base ArticleProductsSatori Architect;Satori OfficeArticle

When running a mail sort, the following error occurs: 
           80040421 – Unable to allocate any sequence numbers
Cause 

The USPS requires that sequence numbers remain unique for 45 days. When the Sequence mail pieces parameter is set to Automatic, the Bulk Mailer system keeps track of the date and the sequence numbers used. The program also looks for a continuous sequential block of numbers large enough for all the records that are being sorted; if it does not find a large enough block of sequential numbers available, it will produce this error.  
Note:  Satori Architect and Office do not allow sequence numbers to be reused for 120 days from the mailing date specified in the sort settings.
Resolution

Obtain another Mailer ID to use until the current Mailer ID’s sequence numbers are released for re-use. Once a second Mailer ID is obtained through the Business Customer Gateway, create a second permit by making a copy of the current one, and use the new Mailer ID in the second permit.

More Information
How to request an additional Mailer ID

Article Number000002802